- Boilers[10]
- Pressure Vessels[1]
- Evaporator[1]
- Drying Equipment[1]
- Contact Person : Ms. Gold Bangzi
- Company Name : Hebei Gold Bangzi Boiler Co., Ltd.
- Tel : 86-0311-82296869
- Fax : 86-0311-82291120
- Address : Hebei,Shijiazhuang,No.66 Shiqing Road Shijiazhuang,Hebei
- Country/Region : China
- Zip : 050204
small vertical steam boiler (0.1-1ton)
characters
vertical steam boiler is the new energy saving product which designed by our company. It is equipped with the device of secondary air, so it is environmental and energy saving. According to the burning mechanism of coal, we adopt a variety of advanced technical measures, firstly, we set combustion zone in the grate surface to vaulted horizontal pipe, not set of heating area, then reduce the water cooling degrees, increase the temperature of ignition zone, which can make the fuel burn fully. Secondly, we set the device of secondary air, which add the oxygen in the burning area, this make the residence time of carbon particles carried in smoke extended greatly, so the coal can get sufficient burning, reduce the heat loss of incomplete combustion and the dust concentration and the blackness of the smoke, so it is environmental.
Parameters:
Model Item | LSH0.1-0.4-AII | LSH0.2-0.4-AII | LSH0.3-0.4-AII | LSH0.5-0.4-AII | LSH0.75-0.4-AII | LSH0.95-0.4-AII |
nominal capacity
| 0.1 | 0.2 | 0.3 | 0.5 | 0.75 | 0.95 |
nominal steam pressure | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
nominal feed water temperature | 20 | 20 | 20 | 20 | 20 | 20 |
nominal steam temperature | 152 | 152 | 152 | 152 | 152 | 152 |
heating area | 4.3 | 9.4 | 12.5 | 20 | 25 | 32 |
design efficiency | 68 | 68 | 68 | 68 | 68 | 68 |
the way of combustion | hand grate | hand grate | hand grate | hand grate | hand grate | hand grate |
appearance and size | 816*2630 | 1016*3042 | 1116*3286 | 1320*3800 | 1524*4300 | 1624*4565 |
Model Item | LSH0.1-0.7-AII | LSH0.2-0.7-AII | LSH0.3-0.7-AII | LSH0.5-0.7-AII | LSH0.75-0.7-AII | LSH0.95-0.7-AII |
Nominal capacity | 0.1 | 0.2 | 0.3 | 0.5 | 0.75 | 0.95 |
Nominal steam pressure | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
Nominal feed water temperature | 20 | 20 | 20 | 20 | 20 | 20 |
Nominal steam temperature | 170 | 170 | 170 | 170 | 170 | 170 |
Heating area | 4.3 | 9.4 | 12.5 | 20 | 25 | 32 |
Design efficiency | 68 | 68 | 68 | 68 | 68 | 68 |
Suitable coal | Type II gas coal | Type II gas coal | Type II gas coal | Type II gas coal | Type II gas coal | Type II gas coal |
The way of combustion | hand grate | hand grate | hand grate | hand grate | hand grate | hand grate |
small vertical steam boiler (0.1-1ton)